Emanuele Zanda
Google reviewRead on Google“An excellent experience on the installer training course. The whole team was professional and knowledgeable.”
Cable blowing machines · Made in Italy
From last-mile connections to long-distance runs, a Fibernet technician can help you choose the right machine for your fibre optic cable installation.
Opera, image 1 of 3
Expert advice direct from the manufacturer / Free demonstration on request
Some of our customers.






Keep your installation moving with Fibernet cable blowing machines.
Photos and stories from installers, published by Fibernet.






Read on Google“An excellent experience on the installer training course. The whole team was professional and knowledgeable.”
Read on Google“I had the chance to try the Opera cable blowing machine on site…”
Read on Google“I really enjoyed this course. It took place in a pleasant setting with friendly, helpful people.”
Stories from installers
Hear the results from the installers themselves. Watch their testimonials right here.
Product videos
Three machines. Find your fit.
Start with the job at hand. Our technician can answer your questions about the right setup.

Compact and lightweight
A compact, lightweight machine for short runs.

Pneumatic power
A pneumatic machine for long cable runs.

Electric, with two gears
For short and long runs. Two gears let you match force and speed to the job.
Specifications for the Fibernet range. The speeds shown are maximum values. Actual results depend on installation conditions and machine setup.
Direct from the manufacturer
When you’re working on site, you need practical answers. With Fibernet, you speak directly to the people who design and build your cable blowing machine.
Speak to a technicianA specialist technician can help when you need it.
Spare parts ready to ship, direct from the manufacturer.
If your machine breaks down, a replacement may be available within 48 hours.
Check availability and terms with your technician.Get help making the most of your machine, from your very first job.
See it in action before you choose
Request a free hands-on demonstration on your site or at Fibernet’s test facility. Discuss a real job with the technician.
Request a free demonstration
A successful fiber blower rental enquiry starts with the cable, the duct and the working conditions, rather than a daily hire rate alone. For contractors preparing installations in Italy, choosing suitable equipment means understanding how these elements interact throughout the planned route. Cable outside diameter, duct internal diameter, cable construction, route length and changes in direction all influence machine selection. A compact cable entering a narrow microduct presents different handling requirements from a larger cable entering a wider duct. Before requesting equipment, gather the cable manufacturer's installation limits, the duct specifications and any information about bends, joints or previously occupied sections. This gives the equipment supplier a practical basis for assessing compatibility without relying on assumptions about achievable distance or speed. When discussing fiber cable blower rental with Fibernet, describe the actual installation task and ask which arrangements, if any, are available for your location and dates. Rental availability, machine configuration and contractual conditions require direct confirmation; an enquiry should not be treated as a booking. Fibernet introduced its first cable blowing machine, Lady, in 2021, building on technical experience that reaches back to the early development of optical cable installations in Italy. That background provides relevant context for a discussion centred on machine selection and practical site requirements. The compressor deserves equal attention during planning. A compressed air fiber blower depends on an appropriate air supply, but pressure alone does not establish whether a compressor is suitable. Required airflow, permitted operating pressure, hose configuration and air treatment must be checked against the specifications of the selected machine and installation components. Moisture or contamination can compromise the process, while an unsuitable supply can prevent consistent operation. Ask which compressor characteristics and connection fittings are required before arranging transport to site. Preparation should also cover the cable reel position, a stable working area and sufficient access for operators to observe the cable entering the machine. Establish how the team will communicate between the feeding position and the receiving point, and identify who can stop the operation immediately if resistance changes. Duct condition should be assessed using appropriate procedures before blowing begins, with any cleaning, checking or lubrication carried out according to the relevant equipment and component guidance. For a useful initial conversation, send Fibernet a concise project brief containing the installation location, proposed dates, cable and duct dimensions, available compressor details and expected working duration. Include photographs or technical sheets where possible. This turns a general request into a focused assessment and helps identify missing information early, before equipment commitments or site mobilisation create avoidable costs.
The financial value of fiber blower rental depends on how closely the equipment arrangement matches the working programme. A short installation window can make temporary access worth considering, but the quoted equipment charge is only one part of the calculation. Transport, collection, accessories, compressor provision, consumables and any agreed responsibility for damage can change the total substantially. Before comparing proposals, establish exactly what each quotation includes and what remains the contractor's responsibility. Ask when the chargeable period begins, whether non-working days count and how an extension would be handled if access to the route is delayed. These questions are especially important when the machine must arrive at a constrained roadside site or when the installation is scheduled around permits and other contractors. A meaningful comparison with the fiber blower price for outright purchase should use the same operating assumptions. Consider how often the machine is likely to work over the coming months, whether future projects require the same cable range and who would manage maintenance between assignments. Ownership can suit recurring work, while a temporary arrangement may suit a defined requirement, provided suitable equipment and terms are available. Neither option is automatically cheaper simply because its initial payment is lower. Fibernet can be contacted to discuss its machines and the commercial options available for a particular enquiry, without assuming that rental is offered in every territory. When reviewing fiber optic cable blower rental proposals, request a written description of the supplied configuration. Relevant details can include compatible cable dimensions, duct connection components, cable guiding parts and the documentation provided with the machine. Confirm whether the proposed setup requires additional components for your specific cable and duct combination. An apparently attractive rate loses its value if essential parts are missing when the crew reaches site. Clarify the condition in which equipment must be returned and how inspection, cleaning and any exceptional wear are assessed. Keep the cost discussion connected to realistic output rather than promotional assumptions about installation speed. Actual progress depends on route condition, cable behaviour, air supply and the team's preparation, so no single distance or completion time should be taken for granted. Build a schedule that allows for setup, checks, repositioning and controlled shutdown, not just the time during which the cable moves. For an installation in Italy, also establish the delivery address, site access restrictions and the person authorised to receive the equipment. International enquiries need additional attention to shipping arrangements, customs requirements where applicable and return logistics. Bringing these details into the first discussion helps both sides assess feasibility. The result should be a clearly defined commercial proposal tied to an actual installation requirement, rather than a headline rate that leaves essential operational costs unresolved.
On installation day, the usefulness of fiber blower rental is measured by whether the supplied setup supports controlled, repeatable work. Start with a documented handover rather than assuming that experience with another machine transfers directly. Operators should understand the controls, the permitted cable and duct combinations, the setup sequence and the manufacturer's safety requirements for the specific equipment. Check that the cable contact surfaces and guiding components are appropriate for the cable being installed, and inspect the machine for visible damage before use. Any uncertainty about adjustment or operation should be resolved before the cable is fed into the duct. Fibernet's development as a manufacturer is rooted in a practical technical background. Founded in 2001, the company draws on founder Giancarlo Trinei's experience with early Italian optical cable installations and testing. The arrival of Matteo, Marta and Ismael in the business from 2010 marked a generational transition, while the launch of Lady in 2021 established a specific milestone in its cable blowing machine development. For contractors, the relevant question is how that manufacturing knowledge can inform the selection and use of a fiber cable blower for a defined task. Ask about the documentation and technical assistance available for the proposed machine, including the language, contact method and response arrangements. Do not assume that on-site support, operator instruction or assistance outside normal working hours is included unless it is expressly agreed. During setup, position the reel so that the cable feeds smoothly without unnecessary bending or contact with rough surfaces. Keep the operating area organised and protect hoses and connections from passing vehicles or other site activity. Follow the relevant safety procedures for compressed air, including isolation and depressurisation before disconnecting components or undertaking adjustments that require them. The machine's instructions and the cable manufacturer's limits should guide operating decisions throughout the job. If cable movement becomes irregular, resistance rises unexpectedly or the cable surface shows damage, stop and investigate rather than compensating blindly with additional drive force or pressure. A fiber optic cable blower cannot overcome every obstruction or unsuitable route condition safely. Recording the section worked, cable and duct sizes, equipment settings within permitted limits, interruptions and observed problems can help the team make informed decisions on subsequent sections. At the end of the assignment, allow time for the agreed shutdown, cleaning and return checks. Account for accessories and report any fault promptly so that responsibility and remedial action can be discussed clearly. For customers enquiring from outside Italy, confirm whether the required machine, documentation, shipping and support arrangements can be provided for the destination concerned. Contact Fibernet with those operational details to explore a suitable solution and confirm the commercial arrangements actually available for your project.
Fill in the form and discover what Fibernet Srl can do for you!
Contact us!Before you get started
If you prefer, speak to us directly.
+39 346 652 9915Compare the cable diameter, duct diameter and installation distance. Lady is compact and lightweight for short runs. Opera is pneumatic and designed for long runs. Geniale is electric and handles both. A Fibernet technician can help you choose.
Yes. You can request a free hands-on demonstration on your site or at Fibernet’s test facility. Tell us what you need in the form and a technician will arrange it with you. Request a demonstration.
To get a price, contact a Fibernet adviser using the form or call +39 346 652 9915.
Fibernet offers direct technical support, spare parts ready to ship and dedicated training. If your machine breaks down, a replacement may be available. Ask your technician about availability and terms.
Tell us about your job. We’ll help you find the right cable blowing machine.