Cable blowing machines · Made in Italy

Looking for "drill powered cable blower"?

From last-mile connections to long-distance runs, a Fibernet technician can help you choose the right machine for your fibre optic cable installation.

Expert advice direct from the manufacturer / Free demonstration on request

Some of our customers.

Keep your installation moving with Fibernet cable blowing machines.

On-site training
Worldwide Technical support
Spare parts ready to ship
Replacement machine if yours breaks down

Photos and stories from installers, published by Fibernet.

Cable blowing machines in action.

Three installers testing the Opera cable blowing machine on siteEnlarge +
Opera with the installers on site.
A Fibernet technician showing installers how to use the cable blowing machineEnlarge +
Hands-on demonstration with a Fibernet technician.
Close-up of a Geniale cable blowing machine during an outdoor testEnlarge +
A closer look at Geniale in the field.
GoogleExcellentBased on 176 reviewsRead the reviews

Emanuele Zanda

Google review
Google

“An excellent experience on the installer training course. The whole team was professional and knowledgeable.”

Read on Google

Giuseppe Ares Rosa

Google review
Google

“I had the chance to try the Opera cable blowing machine on site…”

Read on Google

Paolo Manna

Google review
Google

“I really enjoyed this course. It took place in a pleasant setting with friendly, helpful people.”

Read on Google

Stories from installers

See the difference on site.

Testimonial · Opera

“We cut our working time by 80%.”

Experience on site

“2 km of cable in half a day.”

Hear the results from the installers themselves. Watch their testimonials right here.

Product videos

Meet the machines.

Product overview

LADY

Product overview

GENIALE

Product overview

OPERA

Three machines. Find your fit.

Every installation is different.
Find your cable blowing machine.

Start with the job at hand. Our technician can answer your questions about the right setup.

01 / SHORT RUNSFibernet Lady cable blowing machine

Compact and lightweight

LADY

A compact, lightweight machine for short runs.

Cable diameter
1.2–10 mm
Duct diameter
5–16 mm
Pushing force
Up to 150 N
Maximum speed
80 m/min
Cable protection
Twin drive beltsrubber-coated
I’m interested in Lady
02 / LONG RUNSFibernet Opera pneumatic cable blowing machine

Pneumatic power

OPERA

A pneumatic machine for long cable runs.

Cable diameter
4–16 mm
Duct diameter
7–63 mm
Pushing force
Up to 900 N
Maximum speed
110 m/min
Cable protection
Twin drive beltsrubber-coated
I’m interested in Opera
03 / ELECTRIC DRIVEFibernet Geniale electric cable blowing machine

Electric, with two gears

GENIALE

For short and long runs. Two gears let you match force and speed to the job.

Cable diameter
1.2–8 mm
Duct diameter
5–16 mm
Pushing force
400 / 110 NGear 1 / Gear 2
Maximum speed
60 / 125 m/minGear 1 / Gear 2
Cable protection
Twin drive beltsrubber-coated
I’m interested in Geniale

Specifications for the Fibernet range. The speeds shown are maximum values. Actual results depend on installation conditions and machine setup.

Direct from the manufacturer

The machine matters.
Who supports you
matters even more.

When you’re working on site, you need practical answers. With Fibernet, you speak directly to the people who design and build your cable blowing machine.

Speak to a technician

Direct support

A specialist technician can help when you need it.

Spare parts available

Spare parts ready to ship, direct from the manufacturer.

Replacement machine

If your machine breaks down, a replacement may be available within 48 hours.

Check availability and terms with your technician.

Dedicated training

Get help making the most of your machine, from your very first job.

See it in action before you choose

Put it to the test.
On your own site.

Request a free hands-on demonstration on your site or at Fibernet’s test facility. Discuss a real job with the technician.

Request a free demonstration
An operator using an Opera cable blowing machine on site

Choose cable blowing equipment around the job, not assumptions

Choosing a drill powered cable blower starts with understanding the cable and duct combination your installation team actually uses. Cable diameter alone does not establish compatibility: the duct’s internal diameter, cable construction, permitted pushing force and route geometry all influence the equipment specification. For telecommunications contractors working on Italian sites or managing international projects, these details determine whether a proposed configuration deserves further assessment. Fibernet provides a direct point of contact for discussing cable blowing requirements, drawing on a business history that began in 2001 and technical experience rooted in the earliest fibre installations in Italy. The aim of an equipment enquiry should be clear: establish a suitable configuration before committing to a purchase, rather than relying on an attractive headline speed or a distance achieved under different conditions. A drill powered fibre cable blower uses a compatible drill to provide mechanical drive, while compressed air helps move the cable through the duct. The precise arrangement depends on the machine, so drill suitability, drive connection, operating limits and required accessories must be checked against the relevant technical documentation. A cordless drill does not, by itself, remove the need for an appropriate compressed air supply. Buyers should therefore assess the complete working arrangement, including the compressor, air treatment where required, hoses, couplings and available space around the duct entry point. These practical considerations are especially important when crews move between roadside chambers and constrained work areas during the same shift. Before requesting a recommendation, prepare the cable datasheet, the duct dimensions and a realistic description of the intended route. Include known bends, gradients, intermediate access points and whether the duct is new or previously occupied. If several cable sizes are involved, identify the full range rather than only the most common size. This makes it easier to discuss guides, seals and drive components without assuming that one setup covers every application. An effective enquiry also distinguishes required performance from preferred convenience: reducing transport weight, simplifying setup and accommodating an existing drill are different objectives. Fibernet’s first cable blowing machine, Lady, was launched in 2021, marking a significant step in the company’s development of installation equipment. For a prospective buyer, that background provides a useful starting point for a technical conversation, not a substitute for checking the specification of the proposed model. Ask which configuration is appropriate, which components are included and which operating conditions must be maintained. A carefully specified drill powered cable blower can then be evaluated against the work it is expected to perform, with fewer uncertainties about compatibility, site preparation and the resources needed to operate it.

Prepare the duct, control the feed and assess progress realistically

Reliable cable blowing depends as much on preparation and operating discipline as on the machine itself. Before positioning equipment, the installation team should confirm that the duct route is ready, accessible and suitable for the intended operation. Check duct continuity and condition using appropriate procedures, identify damaged sections and verify that connections are suitable for the planned air pressure. Contamination, water, poorly made joints and unexpected restrictions can undermine progress even when the selected machine matches the cable dimensions. A cable blower for fiber optic cable installation should therefore be considered as one part of a controlled working process, rather than a remedy for an unverified route. The starting point also needs enough space for stable machine positioning, safe cable handling and an orderly connection to the compressed air supply. Cable presentation deserves particular attention. The cable should feed from its drum without unnecessary resistance, sharp changes of direction or uncontrolled movement. Drum positioning and handling arrangements should follow the cable supplier’s guidance and the conditions of the site. At the machine, the correct guides and seals help maintain alignment and support the intended operating arrangement. Drive pressure must be appropriate for the cable and equipment: excessive clamping or pushing can damage the cable, while inadequate engagement can cause slipping. Operators should use the manufacturer’s instructions to establish settings, rather than compensating for poor progress by repeatedly increasing force. When assessing a drill powered cable blower, ask how the specified configuration allows the operator to manage feed and respond to changing resistance. A drill driven cable blower also requires attention to the drill’s operating characteristics, connection and permitted settings. Compatibility must be confirmed; the fact that a drill fits physically does not establish that it is suitable for sustained use in the application. Air pressure and flow should likewise remain within the limits of every relevant component, including the duct system. Keep personnel clear of exposed cable movement and follow the equipment’s pressure isolation procedures before adjustment or intervention. A slowing feed rate should prompt investigation of the route, cable supply and setup, not an assumption that greater force is the answer. For project planning, treat installation distance and speed as conditional outcomes. Bends, friction, cable stiffness, duct dimensions, air supply and route condition interact, so figures from another site may not transfer directly. Record the setup and results from initial sections to support more realistic scheduling on comparable work. This approach helps contractors distinguish equipment limitations from preparation issues and reduces avoidable interruptions. Discussing these operational details with Fibernet before selecting equipment gives the purchasing conversation a practical foundation: the proposed machine can be assessed alongside the real conditions in which the team will use it.

Build a purchasing specification for Italian and international projects

For a contractor purchasing cable blowing equipment, the most useful quotation is one that makes the proposed working configuration understandable. Start with the intended application and ask for a clear breakdown of the machine, supplied accessories and any additional components needed for your cable and duct sizes. Establish whether the drill, compressor connection components, interchangeable guides, seals and transport provisions are included or need separate consideration. Avoid assuming that photographs show the exact package being offered. A drill powered cable blower should be assessed as a complete operational purchase, including the external equipment and consumable parts required to put it into service. This is especially relevant when the purchasing team and the installation crew work in different locations. Fibernet combines family ownership with a technical history extending back to founder Giancarlo Trinei’s involvement in early fibre installations in Italy during the 1980s. The company was established in 2001, and a generational transition began in 2010 with Matteo, Marta and Ismael joining the business. That continuity helps explain its focus on developing practical equipment for installation professionals. For English-speaking buyers evaluating Italian-made equipment, the next step is to translate that background into specific purchasing questions: which model is proposed, what application limits apply, and what documentation accompanies the supplied configuration? Written answers are more useful than broad assurances when an installation schedule depends on equipment readiness. When comparing a drill powered fibre optic cable blower with another drive arrangement, consider how each option fits your existing site resources. If a battery powered cable blower is also under consideration, clarify exactly what the battery powers and which external utilities are still required. Product terminology alone does not establish whether compressed air is necessary, how long equipment can operate or which accessories are compatible. Evaluate the full setup, its handling requirements and the availability of suitable power and air at the intended work sites. For international enquiries, provide the delivery destination and ask Fibernet to confirm shipment availability, packing arrangements, lead times and the documentation applicable to the destination. These details should be established before building a deployment schedule around an anticipated arrival date. Contractors serving several markets should also confirm the language of operating instructions and any destination-specific requirements relevant to the proposed equipment. Maintenance planning belongs in the same conversation: ask which parts require routine inspection, which items are replaceable and how to identify the correct replacements. Finally, share the priorities that matter most to your crew, whether these concern transport between locations, changes between cable sizes or straightforward preparation at the duct entrance. Contacting Fibernet through www.fibernetsrl.com with a structured application brief supports a more focused discussion and a quotation grounded in the actual cable blowing work ahead.

Still looking for information about drill powered cable blower?

Fill in the form and discover what Fibernet Srl can do for you!

Contact us!

Before you get started

Have a question?
Start here.

If you prefer, speak to us directly.

+39 346 652 9915
Which cable blowing machine is right for my site?

Compare the cable diameter, duct diameter and installation distance. Lady is compact and lightweight for short runs. Opera is pneumatic and designed for long runs. Geniale is electric and handles both. A Fibernet technician can help you choose.

Can I see the machine in action before I buy it?

Yes. You can request a free hands-on demonstration on your site or at Fibernet’s test facility. Tell us what you need in the form and a technician will arrange it with you. Request a demonstration.

How much does a Fibernet cable blowing machine cost?

To get a price, contact a Fibernet adviser using the form or call +39 346 652 9915.

What support will I get after purchase?

Fibernet offers direct technical support, spare parts ready to ship and dedicated training. If your machine breaks down, a replacement may be available. Ask your technician about availability and terms.

Your next project
starts with the right choice.

Tell us about your job. We’ll help you find the right cable blowing machine.

CallRequest information