Cable blowing machines · Made in Italy

Looking for "drill driven fiber cable blower"?

From last-mile connections to long-distance runs, a Fibernet technician can help you choose the right machine for your fibre optic cable installation.

Expert advice direct from the manufacturer / Free demonstration on request

Some of our customers.

Keep your installation moving with Fibernet cable blowing machines.

On-site training
Worldwide Technical support
Spare parts ready to ship
Replacement machine if yours breaks down

Photos and stories from installers, published by Fibernet.

Cable blowing machines in action.

Three installers testing the Opera cable blowing machine on siteEnlarge +
Opera with the installers on site.
A Fibernet technician showing installers how to use the cable blowing machineEnlarge +
Hands-on demonstration with a Fibernet technician.
Close-up of a Geniale cable blowing machine during an outdoor testEnlarge +
A closer look at Geniale in the field.
GoogleExcellentBased on 176 reviewsRead the reviews

Emanuele Zanda

Google review
Google

“An excellent experience on the installer training course. The whole team was professional and knowledgeable.”

Read on Google

Giuseppe Ares Rosa

Google review
Google

“I had the chance to try the Opera cable blowing machine on site…”

Read on Google

Paolo Manna

Google review
Google

“I really enjoyed this course. It took place in a pleasant setting with friendly, helpful people.”

Read on Google

Stories from installers

See the difference on site.

Testimonial · Opera

“We cut our working time by 80%.”

Experience on site

“2 km of cable in half a day.”

Hear the results from the installers themselves. Watch their testimonials right here.

Product videos

Meet the machines.

Product overview

LADY

Product overview

GENIALE

Product overview

OPERA

Three machines. Find your fit.

Every installation is different.
Find your cable blowing machine.

Start with the job at hand. Our technician can answer your questions about the right setup.

01 / SHORT RUNSFibernet Lady cable blowing machine

Compact and lightweight

LADY

A compact, lightweight machine for short runs.

Cable diameter
1.2–10 mm
Duct diameter
5–16 mm
Pushing force
Up to 150 N
Maximum speed
80 m/min
Cable protection
Twin drive beltsrubber-coated
I’m interested in Lady
02 / LONG RUNSFibernet Opera pneumatic cable blowing machine

Pneumatic power

OPERA

A pneumatic machine for long cable runs.

Cable diameter
4–16 mm
Duct diameter
7–63 mm
Pushing force
Up to 900 N
Maximum speed
110 m/min
Cable protection
Twin drive beltsrubber-coated
I’m interested in Opera
03 / ELECTRIC DRIVEFibernet Geniale electric cable blowing machine

Electric, with two gears

GENIALE

For short and long runs. Two gears let you match force and speed to the job.

Cable diameter
1.2–8 mm
Duct diameter
5–16 mm
Pushing force
400 / 110 NGear 1 / Gear 2
Maximum speed
60 / 125 m/minGear 1 / Gear 2
Cable protection
Twin drive beltsrubber-coated
I’m interested in Geniale

Specifications for the Fibernet range. The speeds shown are maximum values. Actual results depend on installation conditions and machine setup.

Direct from the manufacturer

The machine matters.
Who supports you
matters even more.

When you’re working on site, you need practical answers. With Fibernet, you speak directly to the people who design and build your cable blowing machine.

Speak to a technician

Direct support

A specialist technician can help when you need it.

Spare parts available

Spare parts ready to ship, direct from the manufacturer.

Replacement machine

If your machine breaks down, a replacement may be available within 48 hours.

Check availability and terms with your technician.

Dedicated training

Get help making the most of your machine, from your very first job.

See it in action before you choose

Put it to the test.
On your own site.

Request a free hands-on demonstration on your site or at Fibernet’s test facility. Discuss a real job with the technician.

Request a free demonstration
An operator using an Opera cable blowing machine on site

Select cable blowing equipment around your installation conditions

Choosing a drill driven fiber cable blower starts with understanding the cable and duct combination that your installation team actually uses. A machine should not be selected on appearance, portability or an advertised distance alone. Cable outside diameter, duct internal diameter, cable stiffness, route geometry and available compressed air all influence whether a proposed configuration is suitable. For contractors working on Italian street installations, these details can vary between projects and sometimes between sections of the same route. Before requesting equipment, prepare the cable manufacturer's data sheet, the duct dimensions and a realistic description of the route. This gives the supplier a practical basis for assessing compatibility rather than relying on assumptions about what the equipment might achieve. A drill supplies mechanical drive, while compressed air helps carry the cable along the duct; the drill does not replace the air supply. The relationship between these two inputs needs to be managed within the limits specified for the machine, cable and duct. Excessive feeding force can cause buckling or damage, particularly when progress slows at a restriction. Increasing drive speed is therefore not a substitute for investigating resistance. Operators should follow the equipment instructions and establish suitable settings before attempting a full installation. When evaluating a drill driven fiber optic cable blower, ask which drill characteristics are required, how the drive engages with the cable and which components must match the selected diameters. Confirm whether seals, guides, drive elements and duct connections are included or need to be specified separately. These questions help avoid receiving equipment that requires additional parts before it can be used on site. They also make comparisons between quotations more meaningful, because similar descriptions do not necessarily represent equivalent configurations. Fibernet provides a relevant point of contact for businesses seeking cable blowing equipment from an Italian company with an established technical background. Founded in 2001, the business developed from Giancarlo Trinei's experience working with optical cables since the early 1980s. Its first cable blowing machine, Lady, was launched in 2021. That history gives buyers useful context, but the purchasing decision should still depend on the documented suitability of the proposed equipment for their intended work. Share your installation requirements with Fibernet and ask which available configuration addresses them. For a crew moving between access points, suitability also includes practical handling. Consider where the machine will stand, how the cable reel will be positioned and whether the compressor can be connected without obstructing the working area. A well-planned arrangement reduces avoidable interruptions and helps the operator observe cable entry throughout the operation. The objective is a controlled installation process supported by correctly matched equipment, not simply the highest possible feeding speed.

Prepare the duct, air supply and working area before blowing

An effective cable blowing operation begins before the machine is switched on. The duct route needs to be checked using procedures appropriate to the installation specification, including verification that the intended path is continuous and suitable for the cable. Dirt, water, damaged connections and abrupt changes in direction can affect progress even when the blowing equipment is correctly selected. Where cleaning, proving or other preparation is required, it should be completed before cable insertion. Record any known restrictions and communicate them to the operator so that unexpected resistance can be assessed against the actual route rather than treated as a machine setting problem. Position the cable reel so that the cable feeds smoothly towards the machine without unnecessary bends or contact with abrasive surfaces. The entry path should remain stable as the reel turns, and the team should be able to control payout without pulling against the drive. Keep the work area organised around the reel, machine, air connections and duct entry. On roadside projects in Italy, this arrangement must also fit the site's approved access and safety measures. Equipment convenience should never take precedence over safe positioning or the protection of workers and others nearby. With a drill driven cable blower, drill selection and operation require the same attention as the compressed air connection. Verify the permitted drive arrangement in the manufacturer's documentation, including any requirements concerning speed control, operating mode and attachment. Do not assume that every drill is appropriate or that maximum available torque should be used. Likewise, check the compressor's delivery against the machine's specified requirements and the expected installation conditions. Pressure alone does not describe compressor suitability; available airflow, hose restrictions and connection losses can also influence the result. Use only components rated for the intended operating conditions. During setup, confirm that the selected cable guides, seals and duct adapters correspond to the actual dimensions being used. An incorrectly matched seal can allow excessive leakage, while unsuitable guiding or drive contact can compromise cable handling. Follow the manufacturer's instructions for adjustment and any permitted lubrication, rather than applying an unverified product or increasing contact pressure to overcome another fault. A cable blower for fiber optic cable installation works as part of a complete arrangement, so difficulties should be assessed across the cable supply, drive, air path and duct route. During blowing, maintain communication between the people managing the reel and those observing the receiving point where relevant. If movement becomes irregular or stops, pause and investigate according to the operating procedure instead of repeatedly forcing the cable forward. After the operation, inspect and clean accessible components as instructed, then record useful job details such as cable and duct sizes, route conditions and settings. These records support more informed preparation for subsequent installations without turning one successful job into an unsupported promise about every future route.

Request a quotation that reflects the complete working configuration

A useful quotation describes an equipment configuration that can be evaluated against a real installation requirement. If your business is comparing a drill driven fiber cable blower with other available options, begin by defining the jobs it needs to support. State the cable diameter range, duct dimensions, typical access arrangements and the compressed air equipment already available to your crews. Include any constraints affecting transport, storage or working space. For contractors handling several cable sizes, explain how frequently configurations change, because the parts and adjustment steps required between jobs can influence day-to-day efficiency as much as the initial equipment cost. When considering fiber cable blower price, distinguish the machine itself from the items needed to put it into service. Ask the supplier to identify included components, optional accessories and any equipment that must be sourced separately. Depending on the proposed model, relevant points may include diameter-specific guides, sealing components, duct connections, drill requirements and air connection arrangements. Request confirmation rather than assuming that every item shown in promotional material forms part of the standard supply. A clear scope makes it easier to compare offers and reduces the risk of discovering essential omissions when a crew is ready to start work. Ownership costs also deserve attention. Ask which components are subject to routine inspection or wear, how replacement parts are identified and what maintenance the operator is expected to perform. Clarify the availability of operating documentation, the applicable warranty terms and the process for obtaining technical assistance. These are questions to resolve before ordering, not benefits to assume without confirmation. For companies purchasing across borders, request written details of lead times, delivery arrangements and any documentation relevant to the destination. Agreeing responsibilities for transport and receipt helps purchasing teams plan around actual supply conditions rather than an estimated arrival date without context. Fibernet's background combines a family-founded business with technical experience and the development of its own cable blowing equipment. Giancarlo Trinei established the company in 2001, and the next generation joined the business from 2010. The introduction of Lady in 2021 marked a specific step in that product development. For prospective buyers, these milestones provide company context while leaving room for the essential technical discussion: which current machine, accessories and operating requirements suit the application under consideration? An enquiry should therefore invite a documented recommendation rather than ask only for a headline price. Describe the expected work, provide available cable and duct specifications and identify any uncertainties that need clarification. Through www.fibernetsrl.com, businesses can contact Fibernet to discuss cable blowing equipment and request a quotation based on their requirements. The strongest purchasing decision is one that connects compatibility, site preparation, operating support and supply scope, giving both procurement staff and installation crews a shared understanding of what is being ordered.

Still looking for information about drill driven fiber cable blower?

Fill in the form and discover what Fibernet Srl can do for you!

Contact us!

Before you get started

Have a question?
Start here.

If you prefer, speak to us directly.

+39 346 652 9915
Which cable blowing machine is right for my site?

Compare the cable diameter, duct diameter and installation distance. Lady is compact and lightweight for short runs. Opera is pneumatic and designed for long runs. Geniale is electric and handles both. A Fibernet technician can help you choose.

Can I see the machine in action before I buy it?

Yes. You can request a free hands-on demonstration on your site or at Fibernet’s test facility. Tell us what you need in the form and a technician will arrange it with you. Request a demonstration.

How much does a Fibernet cable blowing machine cost?

To get a price, contact a Fibernet adviser using the form or call +39 346 652 9915.

What support will I get after purchase?

Fibernet offers direct technical support, spare parts ready to ship and dedicated training. If your machine breaks down, a replacement may be available. Ask your technician about availability and terms.

Your next project
starts with the right choice.

Tell us about your job. We’ll help you find the right cable blowing machine.

CallRequest information