Emanuele Zanda
Google reviewRead on Google“An excellent experience on the installer training course. The whole team was professional and knowledgeable.”
Cable blowing machines · Made in Italy
From last-mile connections to long-distance runs, a Fibernet technician can help you choose the right machine for your fibre optic cable installation.
Opera, image 1 of 3
Expert advice direct from the manufacturer / Free demonstration on request
Some of our customers.






Keep your installation moving with Fibernet cable blowing machines.
Photos and stories from installers, published by Fibernet.






Read on Google“An excellent experience on the installer training course. The whole team was professional and knowledgeable.”
Read on Google“I had the chance to try the Opera cable blowing machine on site…”
Read on Google“I really enjoyed this course. It took place in a pleasant setting with friendly, helpful people.”
Stories from installers
Hear the results from the installers themselves. Watch their testimonials right here.
Product videos
Three machines. Find your fit.
Start with the job at hand. Our technician can answer your questions about the right setup.

Compact and lightweight
A compact, lightweight machine for short runs.

Pneumatic power
A pneumatic machine for long cable runs.

Electric, with two gears
For short and long runs. Two gears let you match force and speed to the job.
Specifications for the Fibernet range. The speeds shown are maximum values. Actual results depend on installation conditions and machine setup.
Direct from the manufacturer
When you’re working on site, you need practical answers. With Fibernet, you speak directly to the people who design and build your cable blowing machine.
Speak to a technicianA specialist technician can help when you need it.
Spare parts ready to ship, direct from the manufacturer.
If your machine breaks down, a replacement may be available within 48 hours.
Check availability and terms with your technician.Get help making the most of your machine, from your very first job.
See it in action before you choose
Request a free hands-on demonstration on your site or at Fibernet’s test facility. Discuss a real job with the technician.
Request a free demonstration
Searching for a cable blower on rent is often the starting point for a practical decision: how to equip a crew for a defined installation without committing immediately to purchasing a machine. Before comparing quotations, establish what the equipment must actually handle. Cable outside diameter, duct internal diameter, cable construction and the condition of the installed route all influence suitability. A machine selected only on headline pushing force or advertised distance may not match the conditions encountered on site. For a useful initial discussion, provide the cable and duct specifications, approximate section lengths, available access points and the intended working schedule. These details help turn a general availability enquiry into a meaningful technical assessment. A cable blower for fiber optic cable installation combines controlled mechanical feeding with compressed air to help advance the cable through a suitable duct. Successful operation depends on the complete arrangement, not the machine alone. The compressor must meet the selected equipment’s requirements for pressure, airflow and air quality, while hoses, connections and seals must be compatible with the operating conditions. Duct continuity, tightness and cleanliness also matter. Bends, damaged sections, abrupt changes in direction and water accumulation can affect progress. Checking these factors before mobilisation helps identify problems that extra machine power would not necessarily solve. Operators should always work within the limits specified for the machine, cable, duct and associated components. When requesting a fiber optic cable blower on rent, ask which cable guides, duct clamps and sealing components would accompany the proposed configuration. Confirm whether a compressor is included or must be arranged separately, and establish which consumables remain the customer’s responsibility. Availability, collection or delivery arrangements, hire duration and return conditions should be confirmed in writing before scheduling the crew. It is equally important to clarify the procedure if site conditions differ from those described initially. A quotation becomes much more useful when it identifies the equipment configuration and responsibilities rather than simply stating a daily rate. Fibernet provides a relevant technical point of contact for this evaluation through its experience in developing cable blowing machines. Founded in Italy in 2001, the company introduced its first blowing machine, Lady, in 2021. This background supports a conversation centred on equipment selection and practical requirements. Rental availability, geographical coverage and commercial terms should be requested directly rather than assumed. For contractors working in Italy or organising projects internationally, an enquiry should specify the destination and installation dates from the outset. That allows the discussion to address machine suitability alongside the logistical questions that determine whether a proposed arrangement can support the planned work.
A short installation programme can make temporary equipment access attractive, but a meaningful cost comparison needs more than a hire rate. Start with the number of productive days expected on site, then account for mobilisation, setup, route checks and possible interruptions. If access permissions are delayed or ducts require remedial work, the machine may remain allocated without completing any installation. Understanding how the rental period is calculated is therefore essential. Ask whether charges run from dispatch, collection or another agreed event, and clarify the treatment of weekends, extensions and early returns. These are questions for the quotation, not assumptions to resolve after the equipment arrives. For a cable blower on rent, the overall project cost may include transport, insurance arrangements, a deposit, cleaning requirements and replacement charges for damaged or missing accessories. The applicable items depend on the supplier’s terms and must be verified individually. Compressor provision deserves particular attention because an unsuitable air supply can undermine the value of an otherwise appropriate machine. Establish whether the existing compressor can satisfy the required operating conditions and whether the necessary connections are available. Also check how suitable lubricant and replacement seals will be sourced. Small omissions can create disproportionate delays when a crew is already assembled beside an open access point. If your business has recurring installation work, compare temporary access with ownership over a realistic workload rather than a single project. A fiber cable blower price should be assessed against the actual configuration offered, the expected utilisation and the responsibilities that ownership brings. Purchasing may provide greater control over scheduling, while renting may reduce the commitment associated with an occasional requirement. Neither option is automatically preferable. Include storage, inspection, maintenance, transport and staff familiarity in the comparison. Equipment that fits the work and is ready when needed can be more valuable than an apparently cheaper option that repeatedly requires additional arrangements before use. Fibernet’s Italian manufacturing background gives contractors a direct route to discuss its machines and request product information. For international enquiries, specify the delivery destination and ask which supply arrangements can be offered for that location. Do not treat purchase delivery terms as evidence that equivalent rental arrangements are available. A clear enquiry distinguishes the desired commercial option from the technical configuration being considered. It should also identify the contracting company, anticipated dates and the person responsible for equipment acceptance. This makes it easier to obtain an answer that addresses the real decision: whether the proposed machine, associated equipment and commercial conditions fit the work. Comparing quotations on that common basis supports a more reliable decision than comparing isolated headline figures.
The most useful equipment enquiry describes how the crew intends to work, not just which machine it wants. Consider the available space around each access point, the position of the cable drum and the route between the drum and machine entry. The cable should approach the feeding mechanism in accordance with the manufacturer’s guidance, without avoidable strain or bends tighter than the cable specification permits. Drum handling arrangements must also suit the site. Restricted pavement space, passing vehicles, uneven ground and shared work areas can affect the practical setup. Identifying these constraints early helps the equipment discussion reflect the conditions that operators will actually face. Before using a fibre cable blower, verify the proposed cable and duct combination against the equipment documentation. Check that the correct guides, seals and clamping components are present and inspect them for damage or wear. Route preparation should follow the applicable installation procedure, including appropriate checks of duct condition and continuity. The crew should understand how the machine’s controls work, how to stop feeding and how to isolate compressed air safely. A pressurised system must not be opened until it has been isolated and depressurised according to the relevant instructions. Equipment familiarity and a clear working procedure are essential; temporary possession of a machine is not a substitute for competent operation. During installation, monitor cable feeding behaviour and the available machine indications rather than attempting to maintain progress at any cost. Unexpected resistance, slipping or repeated stoppages warrant investigation. Increasing force or pressure without identifying the cause can place the cable, duct or equipment at risk. The correct response depends on the machine instructions and the installation conditions. Keep communication clear between personnel managing the drum and those operating the blowing equipment. Recording section details, operating observations and the reason for any interruption can help the crew make informed decisions on subsequent sections without assuming that every route will behave identically. These operational considerations should shape any request for a cable blower on rent. Ask what documentation accompanies the machine, which checks are expected before use and who should be contacted if a technical question arises. Confirm the process for reporting faults and whether any replacement arrangements are included in the agreement. At the end of the assignment, follow the agreed cleaning, inspection and return procedure, recording the condition of the equipment and accessories. Fibernet’s development of Lady reflects its focus on cable blowing machinery, supported by a company history rooted in practical technical experience. Contacting the team with a clear site brief allows you to discuss relevant machine information and establish which commercial options are available. For projects in Italy and enquiries from overseas, that preparation supports a more precise conversation without assuming unconfirmed rental coverage, equipment specifications or service commitments.
Fill in the form and discover what Fibernet Srl can do for you!
Contact us!Before you get started
If you prefer, speak to us directly.
+39 346 652 9915Compare the cable diameter, duct diameter and installation distance. Lady is compact and lightweight for short runs. Opera is pneumatic and designed for long runs. Geniale is electric and handles both. A Fibernet technician can help you choose.
Yes. You can request a free hands-on demonstration on your site or at Fibernet’s test facility. Tell us what you need in the form and a technician will arrange it with you. Request a demonstration.
To get a price, contact a Fibernet adviser using the form or call +39 346 652 9915.
Fibernet offers direct technical support, spare parts ready to ship and dedicated training. If your machine breaks down, a replacement may be available. Ask your technician about availability and terms.
Tell us about your job. We’ll help you find the right cable blowing machine.